14 © 2008-2009, Analytica GmbH, D-76137 Karlsruhe, Vorholzstr. 36 18.05.2009
2 Configuration
2.1 Initial installation
First the AnaGate CAN Gateway must be supplied via one of the two power plugs with a
tension from 9 to 24 V. Also keep it away from direct sunlight.
Insert the LAN cable into the plug labelled LAN and connect it either to a hub or switch, or
directly to the PC using a crossover cable.
The AnaGate CAN Gateway is delivered with the following settings:
Type of address: Static
IP address: 192.168.1.254
Network mask: 255.255.255.0
Gateway: 192.168.1.1
The device can now be configured using a standard browser (Internet Explorer, Mozilla, etc.)
by using http://192.168.1.254.
Chart 2-1: Browser interface (AnaGate CAN duo)
The PC used for the configuration must be in the 192.168.1.x network. The static IP address
192.168.1.2 with the subnet mask 255.255.255.0 can be e.g. used.